RadiLink
The unique Analong Glasfiberlink for EMC-measurements
Low Loss - High dynamic range - Broadband
The RadiLink ® is an analog fiber optical link with high dynamic range of 85 dB and a bandwidth of 9 kHz to 3 GHz. This makes the optical link ideal for the use in EMC test environments. The optical link can be used to replace the coaxial cable.
Low Loss (gain)
Coaxial cables typically have a loss in between 0,1 dB and 1 dB per meter depending on the type/quality of cable and the frequency. Certainly in applications at higher frequency and with long cables, like in a large EMC chamber of at an Open Area Test Site, the signal loss on the cable will result into large measurement errors. The RadiLink® RF optical link is the solution to this problem and provides a small gain and therefore will solve the loss problems on the coaxial cable.
High Dynamic Range
With regular fiber optic links the dynamic range is too low for use in EMC applications. The RadiLink® RF optical link provides an unprecedented 85 dB dynamic range suitable for almost all EMC apllications. In fact the high dynamic range in combination with the low loss will improve the performance of most EMI measurement receivers.
Technical specifications
|
RadiLink® RF analog Fiber Optical link | ||
|
Performance |
|
Frequency range |
: |
9 kHz - 3 GHz |
|
Input/Output impedance |
: |
50 Ohm |
|
Dynamic Response |
: |
+/- 3 dB maximum (typical +/- 2 dB) |
|
Dynamic Range, |
: |
> 80 dB (typicla 85 dB) |
|
Connectors (input/output) |
: |
SMA |
|
Link Loss |
: |
+0 dB gain |
|
Noise Figure |
: |
Typical 17 dB @ 100 MHz |
|
VSWR (input) |
: |
< 1:2 (<2 GHz) / < 1:2.5 (> 2GHz) |
|
VSWR (output) |
: |
< 1:2 |
|
Environment Conditions | ||
|
Temperature reach |
: |
15° to 35° Celsius |
|
Relative moisture |
: |
10 – 90% (non-condensing) |
|
Compliance |
: |
EMC (EN61326); LVD (EN61010); LASER SAFETY (IEC60825) |
|
Immunity to radiated fields |
: |
200 V/m (9 kHz - 3 GHz) |
|
Mechanical | ||
|
RadiLink remote unit |
: |
120 x 50 x 30 mm (L*W*H) |
|
Weight |
: |
Approx. 200 gram |
|
LASER specifications | ||
|
LASER classification |
: |
Class IIIb |
|
LASER power |
: |
Max. 0,5 Watt output at aperture, 808 nm (only for LASER power supply) |
|
Digital LASER |
: |
Control unit max. 2 mW, 1310 nm / Remote unit max. 2 mW, 1550 nm |
|
Analog LASER (remote unit) |
: |
Max. 5 mW, 1310 nm |
|
Connectors |
: |
FC/PC (LASER power), SC/PC (digital data), E2000/APC7 (analog data) |
|
Standard fiber cable length |
: |
25 meter (optionally any length can be ordered) |
|
Safety measures |
: |
LED indications for LASER ON, Audio warning signals and redundant closed loop system |
|
LASER switch ON/OFF time |
: |
Approximately 10 ms |
Resellers
Find a complete list of resellers here.
Brochure
A brochure for the RadiLink can be found here (English).
Use our contact form for more information about the RadiLink® RF optical link or any of the other products of DARE!! Instruments.
You can also call or e-mail us. Please see the contact information above.
D.A.R.E!! Instruments
Vijzelmolenlaan 7
3447 GX Woerden - The Netherlands
Tel.: +31 348 416 592
Fax.: +31 348 499 732
e-mail: instruments@dare.nl